Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Sports Med ; 52(5): 1292-1298, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38506922

RESUMO

BACKGROUND: The glenoid track concept is used to determine preoperatively whether a Hill-Sachs defect is engaging or not. Currently, the glenoid track concept relies on measurements of bony structures as well as on the confines and elasticity of the rotator cuff as a reference point, which varies extensively among individuals and therefore limits the reliability and accuracy of this concept. PURPOSE: To evaluate the reliability of the global track concept, which determines the angular distance of the Hill-Sachs defect from the center of the articular surface of the humeral head as a new reference point with the help of an automated image analysis software and 3-dimensional analysis of the humeral head. STUDY DESIGN: Controlled laboratory study. METHODS: Computed tomography scans of 100 patients treated for anterior shoulder instability with different sizes of Hill-Sachs defects were evaluated manually by 2 orthopaedic surgeons independently using the software OsiriX as well as automatically by using a dedicated prototype software (ImFusion). Obtained manual and automated measurements included the Hill-Sachs length, Hill-Sachs width, and Hill-Sachs depth of the defect; the Hill-Sachs interval (HSI); and the glenoid width for the glenoid track concept, as well as the angular distance of the Hill-Sachs defect from the center of the articular surface of the humeral head (global track concept). The reliability of the different measurement techniques was compared by calculating intraclass correlation coefficients (ICCs). RESULTS: There was a significant difference for all obtained parameters comparing manual and automatic measurements. For manually obtained parameters, measurements referring to bony boundaries (glenoid width, Hill-Sachs length, and Hill-Sachs width) showed good to excellent agreement (ICC, 0.86, 0.82, and 0.62, respectively), while measurements referring to soft tissue boundaries (HSI and glenoid track; ICC, 0.56 and 0.53, respectively) or not directly identifiable reference points (center of articular surface and global track) only showed fair reliability (ICC middle excursion, 0.42). When the same parameters were measured with the help of an automated software, good reliability for the glenoid track concept and excellent reliability for the global track concept in the middle excursion were achieved. CONCLUSION: The present study showed that the more complex global track measurements of humeral defects are more reliable than the current standard HSI and glenoid track measurements. However, this is only true when automated software is used to perform the measurements. CLINICAL RELEVANCE: Future studies using the new proposed method in combination with an automated software need to be conducted to determine critical threshold values for defects prone to engagement.


Assuntos
Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Humanos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Reprodutibilidade dos Testes , Ombro , Luxação do Ombro/diagnóstico por imagem , Luxação do Ombro/cirurgia , Cabeça do Úmero/diagnóstico por imagem , Cabeça do Úmero/cirurgia
2.
Orthop J Sports Med ; 12(2): 23259671231222938, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38352173

RESUMO

Background: The presence of glenoid bone defects is indicative in the choice of treatment for patients with anterior shoulder instability. In contrast to traditional linear- and area-based measurements, techniques such as the consideration of glenoid concavity have been proposed and validated. Purpose: To compare the reliability of linear (1-dimensional [1D]), area (2-dimensional [2D]), and concavity (3-dimensional [3D]) measurements to quantify glenoid bone loss performed manually and to analyze how automated measurements affect reliability. Study Design: Cohort study (diagnosis); Level of evidence, 3. Methods: Computed tomography images of 100 patients treated for anterior shoulder instability with differently sized glenoid defects were evaluated independently by 2 orthopaedic surgeons manually using conventional software (OsiriX; Pixmeo) as well as automatically with a dedicated prototype software program (ImFusion Suite; ImFusion). Parameters obtained included 1D (defect diameter, best-fit circle diameter), 2D (defect area, best-fit circle area), and 3D (bony shoulder stability ratio) measurements. Mean values and reliability as expressed by the intraclass correlation coefficient [ICC]) were compared between the manual and automated measurements. Results: When manually obtained, the measurements showed almost perfect agreement for 1D parameters (ICC = 0.83), substantial agreement for 2D parameters (ICC = 0.79), and moderate agreement for the 3D parameter (ICC = 0.48). When measurements were aided by automated software, the agreement between raters was almost perfect for all parameters (ICC = 0.90 for 1D, 2D, and 3D). There was a significant difference in mean values between manually versus automatically obtained measurements for 1D, 2D, and 3D parameters (P < .001 for all). Conclusion: While more advanced measurement techniques that take glenoid concavity into account are more accurate in determining the biomechanical relevance of glenoid bone loss, our study showed that the reliability of manually performed, more complex measurements was moderate.

3.
Phys Rev Lett ; 113(11): 113903, 2014 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-25259981

RESUMO

We propose an experimental arrangement to image, with attosecond resolution, transient surface plasmonic excitations. The required modifications to state-of-the-art setups used for attosecond streaking experiments from solid surfaces only involve available technology. Buildup and lifetimes of surface plasmon polaritons can be extracted and local modulations of the exciting optical pulse can be diagnosed in situ.

4.
Phys Rev Lett ; 110(22): 223903, 2013 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-23767726

RESUMO

A compact high repetition rate attosecond light source based on a standard laser oscillator combined with plasmonic enhancement is analyzed. At repetition rates of tens of MHz, we predict focusable pulses with durations of ≲300 as and a spherical wave front at collimation angles ≲5°. Plasmonic mode and guiding of the attosecond radiation determine the beam parameters. The beam is robust with respect to variations of driver pulse focus and duration.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...